When you are looking for highly requested NSN parts, aerospace parts, military and defense parts, and other similar items that trace back to leading manufacturers that you can trust, look no further than Military Supply Chain. We appreciate your interest in part number DT60-W-DTE-DTSC, a Ortho Clinical Diagnostics Inc product we have in stock that is listed alongside the NSN 6630013327886 and the description “Analyzer Clinical C.” If you would like to learn more about part number DT60-W-DTE-DTSC, be sure to fill out and submit the form provided on this page. Within 15 minutes or less, a member of our staff will contact you to present customized pricing and fulfillment options for your comparisons.
Note : We Will Not Share Your Information With Any Third Parties.
For your convenience, we list items like part number DT60-W-DTE-DTSC with all applicable designations. For instance, this item is listed alongside the NSN 6630-01-332-7886, and is categorized under Federal Supply Class (FSC) 6630 Chemical Analysis Instruments. We also carry out testing, inspections, and document verification for much of our inventory, allowing us to guarantee fit, form, and function. With all of this in mind, begin the procurement process for Ortho Clinical Diagnostics Inc part number DT60-W-DTE-DTSC from CAGE Code 03KD1 on our website, and see why so many customers routinely rely on Military Supply Chain for their needs.
MRC | Criteria | Characteristic |
---|---|---|
DPTH | Depth | 14.000 INCHES |
CBBL | Features Provided | BATCH PROCESSING AND DATA ENTRY KEYBOARD AND DISCRETE PROCESSING AND INTEGRAL PRINTER AND RS232 PORT AND STAT PROCESSING |
ELEC | Voltage In Volts | 110.0 AND 240.0 |
MRC | Decoded Requirement | Clear Text Reply |
ACDC | Current Type | AC |
CYFV | Method Of Analysis | COLORIMETRIC AND KINETIC ENZYME/RATE TEST AND POTENTIOMETRIC/ION SELECTIVE ELECTRODE |
CYFZ | Test Sample/Specimen Size | 12.0 MICROLITERS |
CYGD | Throughput Per Hour | 50 SAMPLES/SPECIMENS MINIMUM |
ACZB | Frequency Rating | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL |
CYFW | Wavelength Range Data Non-Availability | NOT INCLUDED AS AN ESSENTIAL CHARACTERISTIC IN THE SPECIFICATION/CID COVERING THIS STANDARD NSN |
CYFY | Analysis Test/Measurement Range | ALBUMIN 3-5 G/DL; AMYLASE 5-900 U/L; CREATINE 0.1-15 MG/DL; GLUCOSE 20-450 MG/DL; UREA NITROGEN 1-100 MG/DL; PHOSPHORUS 0.5-13 MG/DL; TOTAL BILIRUBIN 0.1-20 MG/DL; TOTAL PROTEIN 2-11 G/DL; ASPARTATE AMINOTRANSFERASE (AST) 4-950 U/L; ALANINE AMINOTRANSFERASE (ALT) 3-950 U/L; CREATINEKINASE (CK) 20-1600 U/L; CALCIUM 3-15 MG/DL; SODIUM 95-215 MMO1/L; POTASSIUM 1-11 MMQ1/L; CHLORIDE 65-140 MMO1/L; CARBON DIOXIDE 5-50 MMO1/L |
CYGE | Test Sample/Specimen Delivery Device | PIPET, HANDHELD AUTOMATIC |
AKYD | Accessory Components And Quantity | PIPETTE(S) |
FEAT | Special Features | DRY CHEMICAL TECHNOLOGY; SOLID STATE |
AQXY | Test Type For Which Designed | ALBUMIN; AMYLASE; CREATININE; GLUCOSE; UREA NITROGEN; PHOSPHORUS; TOTAL BILIRUB; TOTAL PROTEIN; ASPARTATE AMINOTRANSFERASE,(AST); ALANINE AMINOTRANSFERASE,(ALT); CREATINE KINASE (CK); CALCIUM; SODIUM; POTASSIUM; CHLORIDE; CARBON DIOXIDE |
ABRN | Height | 7.000 INCHES |
WDTH | Width | 42.000 INCHES |
CYFX | Electrode Type | CALCIUM/CA++ AND CARBON DIOXIDE/CO2 AND CHLORIDE/CL- AND POTASSIUM/K+ AND SODIUM/NA+ |