When you are looking for highly requested NSN parts, aerospace parts, military and defense parts, and other similar items that trace back to leading manufacturers that you can trust, look no further than Military Supply Chain. We appreciate your interest in part number NEF425030-50DEGC, a Challenger Electrical Equipment Corp product we have in stock that is listed alongside the NSN 5925000626922 and the description “Circuit Breaker.” If you would like to learn more about part number NEF425030-50DEGC, be sure to fill out and submit the form provided on this page. Within 15 minutes or less, a member of our staff will contact you to present customized pricing and fulfillment options for your comparisons.
For your convenience, we list items like part number NEF425030-50DEGC with all applicable designations. For instance, this item is listed alongside the NSN 5925000626922, and is categorized under Federal Supply Class (FSC) . We also carry out testing, inspections, and document verification for much of our inventory, allowing us to guarantee fit, form, and function. With all of this in mind, begin the procurement process for Challenger Electrical Equipment Corp part number NEF425030-50DEGC from CAGE Code on our website, and see why so many customers routinely rely on Military Supply Chain for their needs.
Description
Request a Quote
NSN Information for Part Number NEF425030-50DEGC with NSN 5925-00-062-6922, 5925000626922
Characteristics Data of NSN 5925-00-062-6922, 5925000626922
| MRC | Criteria | Characteristic |
|---|---|---|
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 5.125 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
| CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
| AKPX | Pole Quantity | 2 |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 480.0 AC AND |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 15000.0 AC AND |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 DC ALL LOCATIONS |
| FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.378 INCHES NOMINAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
| CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CRCF | Trip Release Ambient Temp Rating | 50.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
| AJEC | Boss Height | 0.188 INCHES NOMINAL |
| AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
| CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| ADAT | Body Width | 2.750 INCHES NOMINAL |
| CPRW | Actuator Function | TRIP-RESET |
| ADTV | Case Material | PLASTIC |
| MRC | Decoded Requirement | Clear Text Reply |
| ADAQ | Body Length | 6.062 INCHES NOMINAL |
| TTQY | Terminal Type And Quantity | 4 COMPRESSION |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 5.219 INCHES NOMINAL |
| ADAU | Body Height | 3.406 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC AND |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.375 INCHES NOMINAL |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 DC ALL LOCATIONS |
| AEBV | Unthreaded Mounting Hole Diameter | 0.225 INCHES NOMINAL |
| CPRQ | Reset Method | MANUAL |